ds005270/sub-106/func/sub-106_task-nbk_bold.json

190 lines
4.5 KiB
JSON

{
"aor": 0.0004212075471698114,
"aqi": 0.02117195924528302,
"bids_meta": {
"AcquisitionMatrixPE": 64,
"AcquisitionNumber": 1,
"AcquisitionTime": "11:27:42.210000",
"BandwidthPerPixelPhaseEncode": 65.104,
"BaseResolution": 64,
"CoilString": "t:HEA;HEP",
"ConversionSoftware": "dcm2niix",
"ConversionSoftwareVersion": "v1.0.20210317",
"DerivedVendorReportedEchoSpacing": 0.000480001,
"DeviceSerialNumber": "35120",
"DwellTime": 2.9e-6,
"EchoTime": 0.027,
"EffectiveEchoSpacing": 0.000240001,
"FileSize": 0.04648868180811405,
"FileSizeUnits": "GB",
"FlipAngle": 70,
"ImageComments": "fMRI 147 (89)",
"ImageOrientationPatientDICOM": [
0.999417,
0.0227174,
-0.0254731,
-0.0303602,
0.932708,
-0.359352
],
"ImageType": [
"ORIGINAL",
"PRIMARY",
"M",
"ND",
"NORM",
"MOSAIC"
],
"ImagingFrequency": 123.227,
"InPlanePhaseEncodingDirectionDICOM": "COL",
"InstitutionAddress": "Bathurst Street 3560,Toronto ,Ontario,CA,M6A 2E1",
"InstitutionName": "Baycrest Health Sciences",
"InstitutionalDepartmentName": "Diagnostic Imaging Department",
"MRAcquisitionType": "2D",
"MagneticFieldStrength": 3,
"Manufacturer": "Siemens",
"ManufacturersModelName": "TrioTim",
"Modality": "MR",
"NumberOfVolumes": 266,
"ParallelReductionFactorInPlane": 2,
"PartialFourier": 1,
"PatientPosition": "HFS",
"PercentPhaseFOV": 100,
"PercentSampling": 100,
"PhaseEncodingDirection": "j-",
"PhaseEncodingSteps": 64,
"PhaseResolution": 1,
"PixelBandwidth": 2694,
"ProcedureStepDescription": "VB17 NMatrix 12 Ch Head fMRI Projects^Head Active fMRI Projects",
"ProtocolName": "OB_AX_ep2d_bold~ 266",
"PulseSequenceDetails": "%SiemensSeq%\\ep2d_bold",
"ReceiveCoilName": "HeadMatrix",
"ReconMatrixPE": 64,
"RefLinesPE": 32,
"RepetitionTime": 2,
"SAR": 0.125132,
"ScanOptions": "FS",
"ScanningSequence": "EP",
"SequenceName": "*epfid2d1_64",
"SequenceVariant": "SK",
"SeriesDescription": "OB_AX_ep2d_bold~ 266",
"SeriesNumber": 8,
"ShimSetting": [
-91,
28254,
-3256,
1025,
285,
65,
-398,
-98
],
"SliceThickness": 3,
"SliceTiming": [
1.005,
0,
1.055,
0.05,
1.105,
0.1,
1.155,
0.15,
1.205,
0.2,
1.255,
0.25,
1.305,
0.3,
1.355,
0.3525,
1.405,
0.4025,
1.455,
0.4525,
1.505,
0.5025,
1.555,
0.5525,
1.605,
0.6025,
1.655,
0.6525,
1.7075,
0.7025,
1.7575,
0.7525,
1.8075,
0.8025,
1.8575,
0.8525,
1.9075,
0.9025,
1.9575,
0.9525
],
"SoftwareVersions": "syngo MR B17",
"SpacingBetweenSlices": 3.48,
"StationName": "MRC35120",
"TaskName": "nbk",
"TotalReadoutTime": 0.01512,
"TxRefAmp": 310.048,
"dataset": "<unset>",
"datatype": "func",
"extension": ".nii.gz",
"modality": "bold",
"subject": "106",
"suffix": "bold",
"task": "nbk"
},
"dummy_trs": 1,
"dvars_nstd": 40.15125098367423,
"dvars_std": 1.0765761672348495,
"dvars_vstd": 0.9765361582954544,
"efc": 0.5618,
"fber": 778.1503,
"fd_mean": 0.09475088311901758,
"fd_num": 12,
"fd_perc": 4.528301886792453,
"fwhm_avg": 2.2268992299413357,
"fwhm_x": 2.2128900000000002,
"fwhm_y": 2.4014599999999997,
"fwhm_z": 2.066347689824007,
"gcor": 0.014802,
"gsr_x": 0.011887789703905582,
"gsr_y": 0.028077738359570503,
"provenance": {
"md5sum": "42ff4a9b0bbc327f479b2e99ae7743fd",
"settings": {
"fd_thres": 0.2,
"testing": false
},
"software": "mriqc",
"version": "24.1.0.dev0+gd5b13cb5.d20240826"
},
"size_t": 265,
"size_x": 64,
"size_y": 64,
"size_z": 40,
"snr": 3.570939638847799,
"spacing_tr": 2.0,
"spacing_x": 3.0,
"spacing_y": 3.0,
"spacing_z": 3.4800000190734863,
"summary_bg_k": 33.9295,
"summary_bg_mad": 11.3909,
"summary_bg_mean": 33.1598,
"summary_bg_median": 19.0,
"summary_bg_n": 116423.0,
"summary_bg_p05": 8.0,
"summary_bg_p95": 113.0,
"summary_bg_stdv": 47.4873,
"summary_fg_k": 1.98,
"summary_fg_mad": 97.7175,
"summary_fg_mean": 499.4708,
"summary_fg_median": 520.0,
"summary_fg_n": 47417.0,
"summary_fg_p05": 162.0,
"summary_fg_p95": 685.0,
"summary_fg_stdv": 145.6184,
"tsnr": 33.79180288198404
}